7 resultados para RESPIRATORY ACIDOSIS
em Instituto Nacional de Saúde de Portugal
Resumo:
Environmental tobacco smoke (ETS) is recognized as an occupational hazard in the hospitality industry. Although Portuguese legislation banned smoking in most indoor public spaces, it is still allowed in some restaurants/bars, representing a potential risk to the workers’ health, particularly for chronic respiratory diseases. The aims of this work were to characterize biomarkers of early genetic effects and to disclose proteomic signatures associated to occupational exposure to ETS and with potential to predict respiratory diseases development. A detailed lifestyle survey and clinical evaluation (including spirometry) were performed in 81 workers from Lisbon restaurants. ETS exposure was assessed through the level of PM 2.5 in indoor air and the urinary level of cotinine. The plasma samples were immunodepleted and analysed by 2D-SDSPAGE followed by in-gel digestion and LC-MS/MS. DNA lesions and chromosome damage were analysed innlymphocytes and in exfoliated buccal cells from 19 cigarette smokers, 29 involuntary smokers, and 33 non-smokers not exposed to tobacco smoke. Also, the DNA repair capacity was evaluated using an ex vivo challenge comet assay with an alkylating agent (EMS). All workers were considered healthy and recorded normal lung function. Interestingly, following 2D-DIGE-MS (MALDI-TOF/TOF), 61 plasma proteins were found differentially expressed in ETS-exposed subjects, including 38 involved in metabolism, acute-phase respiratory inflammation, and immune or vascular functions. On the other hand, the involuntary smokers showed neither an increased level of DNA/chromosome damage on lymphocytes nor an increased number of micronuclei in buccal cells, when compared to non-exposed non-smokers. Noteworthy, lymphocytes challenge with EMS resulted in a significantly lower level of DNA breaks in ETS-exposed as compared to non-exposed workers (P<0.0001) suggestive of an adaptive response elicited by the previous exposure to low levels of ETS. Overall, changes in proteome may be promising early biomarkers of exposure to ETS. Likewise, alterations of the DNA repair competence observed upon ETS exposure deserves to be further understood. Work supported by Fundação Calouste Gulbenkian, ACSS and FCT/Polyannual Funding Program.
Resumo:
A new betacoronavirus-Middle East respiratory syndrome coronavirus (MERS-CoV)-has been identified in patients with severe acute respiratory infection. Although related viruses infect bats, molecular clock analyses have been unable to identify direct ancestors of MERS-CoV. Anecdotal exposure histories suggest that patients had been in contact with dromedary camels or goats. We investigated possible animal reservoirs of MERS-CoV by assessing specific serum antibodies in livestock. METHODS: We took sera from animals in the Middle East (Oman) and from elsewhere (Spain, Netherlands, Chile). Cattle (n=80), sheep (n=40), goats (n=40), dromedary camels (n=155), and various other camelid species (n=34) were tested for specific serum IgG by protein microarray using the receptor-binding S1 subunits of spike proteins of MERS-CoV, severe acute respiratory syndrome coronavirus, and human coronavirus OC43. Results were confirmed by virus neutralisation tests for MERS-CoV and bovine coronavirus. FINDINGS: 50 of 50 (100%) sera from Omani camels and 15 of 105 (14%) from Spanish camels had protein-specific antibodies against MERS-CoV spike. Sera from European sheep, goats, cattle, and other camelids had no such antibodies. MERS-CoV neutralising antibody titres varied between 1/320 and 1/2560 for the Omani camel sera and between 1/20 and 1/320 for the Spanish camel sera. There was no evidence for cross-neutralisation by bovine coronavirus antibodies. INTERPRETATION: MERS-CoV or a related virus has infected camel populations. Both titres and seroprevalences in sera from different locations in Oman suggest widespread infection. FUNDING: European Union, European Centre For Disease Prevention and Control, Deutsche Forschungsgemeinschaft.
Resumo:
Recent studies suggest an association between the Interferon Inducible Transmembrane 3 (IFITM3) rs12252 variant and the course of influenza infection. However, it is not clear whether the reported association relates to influenza infection severity. The aim of this study was to estimate the hospitalization risk associated with this variant in Influenza Like Illness (ILI) patients during the H1N1 pandemic influenza. A case-control genetic association study was performed, using nasopharyngeal/oropharyngeal swabs collected during the H1N1 pandemic influenza. Laboratory diagnosis of influenza infection was performed by RT-PCR, the IFITM3 rs12252 was genotyped by RFLP and tested for association with hospitalization. Conditional logistic regression was performed to calculate the confounder-adjusted odds ratio of hospitalization associated with IFITM3 rs12252. We selected 312 ILI cases and 624 matched non-hospitalized controls. Within ILI Influenza A(H1N1)pdm09 positive patients, no statistical significant association was found between the variant and the hospitalization risk (Adjusted OR: 0.73 (95%CI: 0.33–1.50)). Regarding ILI Influenza A(H1N1)pdm09 negative patients, CT/CC genotype carriers had a higher risk of being hospitalized than patients with TT genotype (Adjusted OR: 2.54 (95%CI: 1.54–4.19)). The IFITM3 rs12252 variant was associated with respiratory infection hospitalization but not specifically in patients infected with Influenza A(H1N1)pdm09.
Resumo:
Two patients, returning to the Netherlands from pilgrimage in Medina and Mecca, Kingdom of Saudi Arabia, were diagnosed with Middle East respiratory syndrome coronavirus (MERS-CoV) infection in May 2014. The source and mode of transmission have not yet been determined. Hospital-acquired infection and community-acquired infection are both possible.
Resumo:
Background: persons who are 65 years or older often spend an important part of their lives indoors thus adverse indoor climate might influence their health status. Objective: to evaluate the influence of indoor air quality and contaminants on older people’s respiratory health. Design: cross-sectional study. Setting: 21 long-term care residences (LTC) in the city of Porto, Portugal. Subjects: older people living in LTC with ≥65 years old. Methods: the Portuguese version of BOLD questionnaire was administered by an interviewer to older residents able to participate (n = 143). Indoor air contaminants (IAC) were measured twice, during winter and summer in 135 areas. Mixed effects logistic regression models were used to study the association between the health questionnaire results and the monitored IAC, adjusted for age, smoking habits, gender and number of years living in the LTC. Results: cough (23%) and sputum (12%) were the major respiratory symptoms, and allergic rhinitis (18%) the main selfreported illness. Overall particulate matter up to 2.5 micrometres in size median concentration was above the reference levels both in winter and summer seasons. Peak values of particulate matter up to 10 micrometres in size (PM10), total volatile organic compounds, carbon dioxide, bacteria and fungi exceeded the reference levels. Older people exposed to PM10 above the reference levels demonstrated higher odds of allergic rhinitis (OR = 2.9, 95% CI: 1.1–7.2). Conclusion: high levels of PM10 were associated with 3-fold odds of allergic rhinitis. No association was found between indoor air chemical and biological contaminants and respiratory symptoms.
Resumo:
A cross-sectional survey was conducted to characterize the indoor air quality (IAQ) in schools and its relationship with children's respiratory symptoms. Concentrations of volatile organic compounds (VOC), aldehydes, PM2.5, PM10, carbon dioxide, bacteria and fungi were assessed in 73 classrooms from 20 public primary schools located in Porto, Portugal. Children who attended the selected classrooms (n = 1134) were evaluated by a standardised health questionnaire completed by the legal guardians; spirometry and exhaled nitric oxide tests. The results indicated that no classrooms presented individual VOC pollutant concentrations higher than the WHO IAQ guidelines or by INDEX recommendations; while PM2.5, PM10 and bacteria levels exceeded the WHO air quality guidelines or national limit values. High levels of total VOC, acetaldehyde, PM2.5 and PM10 were associated with higher odds of wheezing in children. Thus, indoor air pollutants, some even at low exposure levels, were related with the development of respiratory symptoms. The results pointed out that it is crucial to take into account the unique characteristics of the public primary schools, to develop appropriate control strategies in order to reduce the exposure to indoor air pollutants and, therefore, to minimize the adverse health effects.
Resumo:
Few studies have assessed the quality of life (QOL) related to chronic respiratory diseases in the elderly. In the framework of the geriatric study on the health effects of air quality in elderly care centers (GERIA) study, a questionnaire was completed by elderly subjects from 53 selected nursing homes. It included various sections in order to assess respiratory complaints, QOL (World Health Organization QOL (WHOQOL)-BREF), and the cognitive and depression status. The outcome variables were the presence of a score lower than 50 (<50) in each of the WHOQOL-BREF domains (physical health, psychological health, social relationships, and environmental health). Chronic bronchitis, frequent cough, current wheezing, asthma, and allergic rhinitis were considered as potential risk factors. The surveyed sample was (n = 887) 79% female, with a mean age of 84 years (SD: 7 years). In the multivariable analysis, a score of <50 in the physical domain was associated with wheezing in the previous 12 months (odds ratio (OR): 2.03, confidence interval (CI): 1.25-3.31) and asthma (OR: 1.95, CI: 1.12-3.38). The psychological domain was related with a frequent cough (OR: 1.43, CI: 0.95-2.91). A score of <50 in the environmental domain was associated with chronic bronchitis (OR: 2.89, CI: 1.34-6.23) and emphysema (OR: 3.89, CI: 1.27-11.88). In view of these findings, the presence of respiratory diseases seems to be an important risk factor for a low QOL among elderly nursing home residents.