Numerical simulation of a Savonius turbine above an infinite-width forward facing step


Autoria(s): Goh, Seach Chyr; Schlüter, Jorg Uwe
Data(s)

01/04/2016

Resumo

The Savonius turbine, although simple in construction, typically has a maximum power coefficient (cP) of about 0.2. This is significantly lower than the cP of the axial flow propeller-type turbine which typically can be as high as 0.5. However, a simple means to improve the cP of a Savonius turbine is to install it above a forward facing step, for example, a cliff or a building. In this work, prior experimental results of the tow testing of a Savonius turbine installed above a finite-width bluff body were used to validate computational fluid dynamics simulation of the same experimental conditions. The validated simulation settings were then used to obtain the maximum cP of a similar turbine of finite width but installed above an infinite-width forward facing step over a range of installation positions above and behind the step.

Identificador

http://hdl.handle.net/10536/DRO/DU:30085389

Idioma(s)

eng

Publicador

Sage

Relação

http://dro.deakin.edu.au/eserv/DU:30085389/schluter-numericalsimulation-2016.pdf

http://www.dx.doi.org/10.1177/0309524X15624619

Direitos

2016, The Authors

Palavras-Chave #computational fluid dynamics #Savonius wind turbine #roof-mounted #forward facing step #bluff body
Tipo

Journal Article