Small bowel obstruction caused by mesh migration. Case report
Data(s) |
2013
|
---|---|
Resumo |
Introduction. Endoscopic hernia repair methods have become increasingly popular over the past 15 years. Nonetheless, there is no consensus regarding an optimal fixation method. Transabdominal sutures and titanium tacks or staples are the most traditional ones. Case report. We present a case of mechanic small bowel obstruction due to mesh migration occurring one year and a half after incisional hernia repair with polytetrafluoroethylene mesh fixed by spiral tacks. Discussion. Titanium spiral tacks are dangerous because of their sharp components, which can damage organs such as the small intestine, by causing microperforations. The type of prosthesis used has also contributed to the intraluminal migration, since polytetrafluoroethylene mesh is very flexible and poorly integrates in the abdominal wall. Conclusion. A prosthesis of a different material combined with a different fixation system such as absorbable tacks, biological glue, or mechanical tacks without sharp components, would have obviated mesh migration. . |
Formato |
text |
Identificador |
http://eprints.bice.rm.cnr.it/8388/1/article%28128%29.pdf Olmi, Stefano and Uccelli, M. and Cesana, G. and Ciccarese, Francesca and Carrieri, D. and Castello, G. and Legnani, Gian Luca (2013) Small bowel obstruction caused by mesh migration. Case report. Il giornale di chirurgia, 34 (3). pp. 70-73. ISSN 1971-145X |
Idioma(s) |
en |
Publicador |
CIC Edizioni internazionali |
Relação |
http://eprints.bice.rm.cnr.it/8388/ http://www.giornalechirurgia.it/materiale_cic/663_XXXIV_3/5731_small/index.html |
Palavras-Chave | #617 Rami vari della medicina; Chirurgia |
Tipo |
Article PeerReviewed |