Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer


Autoria(s): SALGADO, William L.; BRANDÃO, Luis Eduardo Barreira
Data(s)

29/06/2016

29/06/2016

2013

Resumo

This paper aims to determinate the water flowrate using Time Transient and Cross-Correlation techniques. The detection system uses two NaI(Tl) detectors adequately positioned on the outside of pipe and a gamma-ray source (82Br radiotracer). The water flowrate measurements using Time Transient and Cross-Correlation techniques were compared to invasive conventional measurements of the flowmeter previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowrate values were found to be less than 3% in relation to conventional ones.

Identificador

http://carpedien.ien.gov.br:8080/handle/ien/1787

Idioma(s)

por

Publicador

Instituto de Engenharia Nuclear

Brasil

IEN

Direitos

openAccess

Palavras-Chave #Water Flowrate #Time Transient #Cross-Correlation
Tipo

conferenceObject