Comparison of available measurements of the absolute air-fluorescence yield and determination of its global average value
| Data(s) |
2011
|
|---|---|
| Resumo |
Experimental results of the absolute air-fluorescence yield are given very often in different units (photons/MeV or photons/m) and for different wavelength intervals. In this work we present a comparison of available results normalized to its value in photons/MeV for the 337 nm band at 1013 hPa and 293 K. The conversion of photons/m to photons/MeV requires an accurate determination of the energy deposited by the electrons in the field of view of the experimental set-up. We have calculated the energy deposition for each experiment by means of a detailed Monte Carlo simulation and the results have been compared with those assumed or calculated by the authors. As a result, corrections to the reported fluorescence yields are proposed. These corrections improve the compatibility between measurements in such a way that a reliable average value with uncertainty at the level of 5% is obtained. |
| Formato |
application/pdf |
| Identificador | |
| Idioma(s) |
en |
| Publicador |
American Institute of Physics |
| Relação |
http://eprints.ucm.es/38587/ http://dx.doi.org/10.1063/1.3628711 10.1063/1.3628711 FPA2009-07772 CONSOLIDER CPAN CSD2007-42 910600 |
| Direitos |
info:eu-repo/semantics/openAccess |
| Palavras-Chave | #Física nuclear |
| Tipo |
info:eu-repo/semantics/bookPart PeerReviewed |