Application of calorimetric method for loss measurement of a SynRM drive system
Data(s) |
01/04/2016
|
---|---|
Resumo |
Synchronous reluctance motors (SynRMs) are gaining in popularity in industrial drives due to their permanent magnet-free, competitive performance, and robust features. This paper studies the power losses in a 90-kW converter-fed SynRM drive by a calorimetric method in comparison of the traditional input-output method. After the converter and the motor were measured simultaneously in separate chambers, the converter was installed inside the large-size chamber next to the motor and the total drive system losses were obtained using one chamber. The uncertainty of both measurement methods is analyzed and discussed. |
Formato |
application/pdf |
Identificador |
http://eprints.aston.ac.uk/28448/1/07323832.pdf Aarniovuori, Lassi; Kolehmainen, Jere; Kosonen, Antti; Niemela, Markku; Chen, Huifeng; Cao, Wenping and Pyrhonen, Juha (2016). Application of calorimetric method for loss measurement of a SynRM drive system. IEEE Transactions on Industrial Electronics, 63 (4), pp. 2005-2015. |
Relação |
http://eprints.aston.ac.uk/28448/ |
Tipo |
Article PeerReviewed |