Atom probe field ion microscope measurements of carbon segregation at an a:a grain boundary and service failures by intergranular stress corrosion cracking
Data(s) |
01/01/2006
|
---|---|
Resumo |
This work reports on a critical measurement to understand the intergranular stress corrosion cracking (IGSCC) of pipeline steels: the atom probe field ion microscope (APFIM) measurement of the carbon concentration at a grain boundary (GB). The APFIM measurement was related to the microstructure and to IGSCC observations. The APFIM indicated that the GB carbon concentration of X70 was similar to 10 at% or less, which correlated with a high resistance to IGSCC for X70. (C) 2005 Elsevier Ltd. All rights reserved. |
Identificador | |
Idioma(s) |
eng |
Publicador |
Pergamon Press |
Palavras-Chave | #Materials Science, Multidisciplinary #Metallurgy & Metallurgical Engineering #Grain Boundary Analysis #Pipeline Steel #Carbon Segregation #Stress Corrosion Cracking #X65 Pipeline Steel #Microstructure #Microanalysis #Initiation #Apfim #Iron #X52 #C1 #291499 Materials Engineering not elsewhere classified #650203 Oil and gas |
Tipo |
Journal Article |