Characteristic study, its identification and self-tuned approach to control hydro-power plants


Autoria(s): Raghuvanshi, A. S.; Kishor, Nand; Fraile Ardanuy, José Jesús; Singh, S. P.
Data(s)

01/01/2013

Resumo

The water time constant and mechanical time constant greatly influences the power and speed oscillations of hydro-turbine-generator unit. This paper discusses the turbine power transients in response to different nature and changes in the gate position. The work presented here analyses the characteristics of hydraulic system with an emphasis on changes in the above time constants. The simulation study is based on mathematical first-, second-, third- and fourth-order transfer function models. The study is further extended to identify discrete time-domain models and their characteristic representation without noise and with noise content of 10 & 20 dB signal-to-noise ratio (SNR). The use of self-tuned control approach in minimising the speed deviation under plant parameter changes and disturbances is also discussed.

Formato

application/pdf

Identificador

http://oa.upm.es/29100/

Idioma(s)

eng

Publicador

E.T.S.I. Telecomunicación (UPM)

Relação

http://oa.upm.es/29100/1/INVE_MEM_2013_131811.pdf

http://www.tandfonline.com/doi/abs/10.1080/14786451.2013.774001#.VF3Tnfl5MpI

info:eu-repo/semantics/altIdentifier/doi/10.1080/14786451.2013.774001

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

International Journal of Sustainable Energy, ISSN 1478-6451, 2013-01, Vol. 32, No. 6

Palavras-Chave #Energía Eléctrica #Telecomunicaciones
Tipo

info:eu-repo/semantics/article

Artículo

PeerReviewed