A new basic effect in retarding potential analyzers


Autoria(s): Sanmartín Losada, Juan Ramón; López-Rebollal, Óscar
Data(s)

2000

Resumo

The Retarding Potential Analyzer (RPA) is the standard instrument for in situ measurement of ion temperature and other ionospheric parameters. The fraction of incoming ions rejected by a RPA produces perturbations that reach well ahead of a thin Debye sheath, a feature common to all collisionless, hypersonic flows past ion-rejecting bodies. This phenomenon is here found to result in a correction to Whipple’s classical law for the current characteristic of an ideal RPA sheath thin; inverse ram ion Mach number M-1, and ram angle of RPA aperture u, small or moderately small.

Formato

application/pdf

Identificador

http://oa.upm.es/21653/

Idioma(s)

eng

Publicador

E.T.S.I. Aeronáuticos (UPM)

Relação

http://oa.upm.es/21653/1/A63.pdf

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

Physics of Plasmas, ISSN 1070-664X, 2000, Vol. 7, No. 11

Palavras-Chave #Física #Aeronáutica
Tipo

info:eu-repo/semantics/article

Artículo

NonPeerReviewed