The scaled-time test as an alternative to the pseudo-dynamic test
Data(s) |
1995
|
---|---|
Resumo |
The stepped and excessively slow execution of pseudo-dynamic tests has been found to be the source of some errors arising from strain-rate effect and stress relaxation. In order to control those errors, a new continuous test method which allows the selection of a more suitable time scale factor in the response is proposed in this work. By dimensional analysis, such scaled-time response is obtained theoretically by augmenting the inertial and damping properties of the structure, for which we propose the use of hydraulic pistons which are servo-controlled to produce active mass and damping, nevertheless using an equipment which is similar to that required in a pseudo-dynamic test. The results of the successful implementation of this technique for a simple specimen are shown here. |
Formato |
application/pdf |
Identificador | |
Idioma(s) |
eng |
Publicador |
E.T.S.I. Industriales (UPM) |
Relação |
http://oa.upm.es/16662/1/The_scaled-time_test_as_an_alternative_to_the_pseudo-dynamic_test.pdf http://www.balkema.nl/ |
Direitos |
http://creativecommons.org/licenses/by-nc-nd/3.0/es/ info:eu-repo/semantics/openAccess |
Fonte |
Proceedings 10th European Conference on Earthquake Engineering | 10th European Conference on Earthquake Engineering | 28/08/1994-2/09/1994 | Viena, Austria |
Palavras-Chave | #Ingeniería Civil y de la Construcción |
Tipo |
info:eu-repo/semantics/conferenceObject Ponencia en Congreso o Jornada NonPeerReviewed |