Evaluation offreeze-thaw damage in concrete by ultrasonic imaging
Data(s) |
01/11/2012
|
---|---|
Resumo |
This work studies the use of ultrasonic imaging as an evaluation tool in concrete subjected to freeze–thaw (F–T) cycles. To evaluate the damage in this deterioration process, ultrasonic velocity and attenuation images have been generated from concrete specimens with and without air-entraining agents. Two parameters have been proposed from these ultrasonic images according to our experimental setup: the non-assessable area proportion (NAAP) and a weighted average velocity in terms of the NAAP. The proposed parameters have been compared with the recommended failure criteria of the ASTM and Rilem standards, which employ ultrasonic contact measurements. The principal advantage of the use of ultrasonic images and the proposed methodology in comparison with the ultrasonic velocity measurements by contact is the possibility of detection of incipient damage caused by accelerated freeze–thaw cycles. |
Formato |
application/pdf |
Identificador | |
Idioma(s) |
eng |
Publicador |
E.U.I.T. Aeronáuticos (UPM) |
Relação |
http://oa.upm.es/15924/1/INVE_MEM_2012_131503.pdf http://www.sciencedirect.com/science/article/pii/S0963869512000709 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.ndteint.2012.05.004 |
Direitos |
http://creativecommons.org/licenses/by-nc-nd/3.0/es/ info:eu-repo/semantics/openAccess |
Fonte |
NDT&E International, ISSN 0963-8695, 2012-11, Vol. 52 |
Palavras-Chave | #Ingeniería Civil y de la Construcción |
Tipo |
info:eu-repo/semantics/article Artículo PeerReviewed |