Adhesión de ionómeros vítreos convencionales a dentina tratada con distintas sustancias


Autoria(s): Ventrera, Verónica; Barrionuevo, María Eugenia Alejandra
Data(s)

15/03/2012

Resumo

El objetivo de este trabajo fue evaluar la fuerza adhesiva de los ionómeros vítreos convencionales a la dentina tratada con ácido fosfórico, con ácido poliacrílico y con solución de hipoclorito de sodio. Los ensayos se realizaron sobre dentina de premolares extraídos por razones ortodóncicas o periodontales, los cuales se asignaron al azar en tres grupos de 10 elementos cada uno. A cada grupo se le practicó un tratamiento distinto (descalcificación, desproteinización o eliminación del barro dentinario). Sobre cada espécimen se le adhirió un cilindro de ionómero vítreo convencional preparado según las especificaciones de su fabricante. Posteriormente las muestras fueron sometidas a fuerzas de cargas de corte utilizando una máquina de ensayos universal (Instron). Los resultados obtenidos fueron sometidos a análisis de ANOVA de una entrada y a post test de comparación múltiple de Tukey. Por lo que puede expresarse que no hubo diferencia estadísticamente significativa (p>0,05) en la fuerza adhesiva de los ionómeros vítreos que fueron adheridos a dentina con tratamiento de ácido poliacrílico, y los que fueron adheridos a dentina con tratamiento de descalcificación (acción del ácido fosfórico). Se encontró diferencia estadísticamente significativa en las muestras adheridas a dentina tratadas con poliacrílico y ácido fosfórico (p<0.01 y p<0.05 respectivamente), con respecto a las que fueron tratadas con hipoclorito.

The goal of this study is to analyse the adhesive force of the conventional vitreous ionomers in the dentin treated with phosphoric and polyacrylic acid and with sodium hypochlorite. The tests were performed on the dentin of premolar teeth extracted due to orthodontic or periodontal reasons. They were chosen at random in three groups of 10 elements each. Each group received a different treatment (decalcification, deproteinization or elimination of smear layer). A cylinder of conventional vitreous ionomer was adhered to each specimen according to the specifications laid down by the manufacturer. Subsequently, the samples were submitted to shear cutting forces using a universal testing machine (Instron). The results were submitted to a one-way ANOVA analysis and a Tukey multiple post comparison test. In conclusion: There was not any statistically relevant difference (p>0.05) in the adhesive force of the vitreous ionomers which were adhered to the dentin with the polyacrylic acid treatment. These ionomers were adhered to the dentin with the decalcification treatment (phosphoric acid action). A statistically relevant difference was found in the samples adhered to the dentin and treated with polyacrylic and phosphoric acid (p<0.01 and p<0.05, respectively) compared to the ones which were treated with hypochlorite.

Fil: Ventrera, Verónica. Universidad Nacional de Cuyo. Facultad de Odontología

Fil: Barrionuevo, María Eugenia Alejandra. Universidad Nacional de Cuyo. Facultad de Odontología

Formato

application/pdf

Identificador

http://bdigital.uncu.edu.ar/6028

Idioma(s)

spa

Publicador

Universidad Nacional de Cuyo. Facultad de Odontología

Direitos

info:eu-repo/semantics/openAccess

http://creativecommons.org/licenses/by/2.5/ar/

Fonte

Revista Facultad de Odontología, Vol. 6, no. 1

http://bdigital.uncu.edu.ar/6004

Palavras-Chave #Dentina #Materiales dentales #Operatoria dental #Recubrimiento dental adhesivo #Ionómeros vítreos
Tipo

article

info:ar-repo/semantics/artículo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion