Systematic analysis of the intravoxel incoherent motion threshold separating perfusion and diffusion effects: Proposal of a standardized algorithm


Autoria(s): Wurnig, Moritz C; Donati, Olivio F; Ulbrich, Erika; Filli, Lukas; Kenkel, David; Thöny, Harriet C.; Boss, Andreas
Data(s)

31/10/2014

Resumo

PURPOSE To systematically evaluate the dependence of intravoxel-incoherent-motion (IVIM) parameters on the b-value threshold separating the perfusion and diffusion compartment, and to implement and test an algorithm for the standardized computation of this threshold. METHODS Diffusion weighted images of the upper abdomen were acquired at 3 Tesla in eleven healthy male volunteers with 10 different b-values and in two healthy male volunteers with 16 different b-values. Region-of-interest IVIM analysis was applied to the abdominal organs and skeletal muscle with a systematic increase of the b-value threshold for computing pseudodiffusion D*, perfusion fraction Fp , diffusion coefficient D, and the sum of squared residuals to the bi-exponential IVIM-fit. RESULTS IVIM parameters strongly depended on the choice of the b-value threshold. The proposed algorithm successfully provided optimal b-value thresholds with the smallest residuals for all evaluated organs [s/mm2]: e.g., right liver lobe 20, spleen 20, right renal cortex 150, skeletal muscle 150. Mean D* [10(-3) mm(2) /s], Fp [%], and D [10(-3) mm(2) /s] values (±standard deviation) were: right liver lobe, 88.7 ± 42.5, 22.6 ± 7.4, 0.73 ± 0.12; right renal cortex: 11.5 ± 1.8, 18.3 ± 2.9, 1.68 ± 0.05; spleen: 41.9 ± 57.9, 8.2 ± 3.4, 0.69 ± 0.07; skeletal muscle: 21.7 ± 19.0; 7.4 ± 3.0; 1.36 ± 0.04. CONCLUSION IVIM parameters strongly depend upon the choice of the b-value threshold used for computation. The proposed algorithm may be used as a robust approach for IVIM analysis without organ-specific adaptation. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Formato

application/pdf

Identificador

http://boris.unibe.ch/66117/1/mrm25506.pdf

Wurnig, Moritz C; Donati, Olivio F; Ulbrich, Erika; Filli, Lukas; Kenkel, David; Thöny, Harriet C.; Boss, Andreas (2014). Systematic analysis of the intravoxel incoherent motion threshold separating perfusion and diffusion effects: Proposal of a standardized algorithm. Magnetic resonance in medicine, 74(5), pp. 1414-1422. Wiley-Liss 10.1002/mrm.25506 <http://dx.doi.org/10.1002/mrm.25506>

doi:10.7892/boris.66117

info:doi:10.1002/mrm.25506

info:pmid:25360990

urn:issn:0740-3194

Idioma(s)

eng

Publicador

Wiley-Liss

Relação

http://boris.unibe.ch/66117/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Wurnig, Moritz C; Donati, Olivio F; Ulbrich, Erika; Filli, Lukas; Kenkel, David; Thöny, Harriet C.; Boss, Andreas (2014). Systematic analysis of the intravoxel incoherent motion threshold separating perfusion and diffusion effects: Proposal of a standardized algorithm. Magnetic resonance in medicine, 74(5), pp. 1414-1422. Wiley-Liss 10.1002/mrm.25506 <http://dx.doi.org/10.1002/mrm.25506>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed