Structure-function Relationships Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry


Autoria(s): Leite, Mauro T.; Zangwill, Linda M.; Weinreb, Robert N.; Rao, Harsha L.; Alencar, Luciana M.; Medeiros, Felipe A.
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

07/11/2013

07/11/2013

2012

Resumo

Purpose: To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). Methods: Four hundred twenty-two eyes (78 healthy, 210 suspects, 134 glaucomatous) of 250 patients were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study and from the African Descent and Glaucoma Evaluation Study. All eyes underwent testing with the Cirrus SDOCT and SAP within a 6-month period. The relationship between parapapillary retinal nerve fiber layer thickness (RNFL) sectors and corresponding topographic SAP locations was evaluated using locally weighted scatterplot smoothing and regression analysis. SAP sensitivity values were evaluated using both linear as well as logarithmic scales. We also tested the fit of a model (Hood) for structure-function relationship in glaucoma. Results: Structure was significantly related to function for all but the nasal thickness sector. The relationship was strongest for superotemporal RNFL thickness and inferonasal sensitivity (R(2) = 0.314, P < 0.001). The Hood model fitted the data relatively well with 88% of the eyes inside the 95% confidence interval predicted by the model. Conclusions: RNFL thinning measured by the Cirrus SDOCT was associated with correspondent visual field loss in glaucoma.

Optovue Inc

Optovue Inc

Topcon

Topcon

Heidelberg Engineering

Heidelberg Engineering

Carl Zeiss Meditec

Carl Zeiss Meditec

CAPES Ministry of Education of Brazil

CAPES Ministry of Education of Brazil [BEX1327/09-7]

Alcon Laboratories Inc.

Alcon Laboratories Inc.

Allergan

Allergan

Pfizer Inc.

Pfizer Inc.

SANTEN Inc.

SANTEN Inc.

NEI [EY08208, EY11008]

NEI

Identificador

JOURNAL OF GLAUCOMA, PHILADELPHIA, v. 21, n. 1, supl. 1, Part 2, pp. 49-54, JAN, 2012

1057-0829

http://www.producao.usp.br/handle/BDPI/43325

10.1097/IJG.0b013e31822af27a

http://dx.doi.org/10.1097/IJG.0b013e31822af27a

Idioma(s)

eng

Publicador

LIPPINCOTT WILLIAMS & WILKINS

PHILADELPHIA

Relação

JOURNAL OF GLAUCOMA

Direitos

closedAccess

Copyright LIPPINCOTT WILLIAMS & WILKINS

Palavras-Chave #STRUCTURE-FUNCTION #RETINAL NERVE FIBER LAYER #SPECTRAL-DOMAIN OCT #STANDARD AUTOMATED PERIMETRY #GLAUCOMA #CIRRUS #RETINAL NERVE-FIBER #SCANNING LASER POLARIMETRY #ENHANCED CORNEAL COMPENSATION #LAYER THICKNESS #OCULAR HYPERTENSION #LINEAR-MODEL #GLAUCOMA #SENSITIVITY #DAMAGE #VARIABILITY #OPHTHALMOLOGY
Tipo

article

original article

publishedVersion