Microtensile bond strength of resin composite to dentin treated with Er:YAG laser of bleached teeth


Autoria(s): Leonetti, Eduardo dos Santos; Rodrigues, Jose Augusto; Reis, Andre Figueiredo; Navarro, Ricardo Scarparo; Aranha, Ana Cecilia Corrêa; Cassoni, Alessandra
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

05/11/2013

05/11/2013

2012

Resumo

The objective of this study was to evaluate the influence of Er:YAG laser (lambda = 2.94 mu m) on microtensile bond strength (mu TBS) and superficial morphology of bovine dentin bleached with 16% carbamide peroxide. Forty bovine teeth blocks (7 x 3 x 3 mm(3)) were randomly assigned to four groups: G1- bleaching and Er:YAG irradiation with energy density of 25.56 J/cm(2) (focused mode); G2 - bleaching; G3 - no-bleaching and Er:YAG irradiation (25.56 J/cm(2)); G4 - control, non-treated. G1 and G2 were bleached with 16% carbamide peroxide for 6 h during 21 days. Afterwards, all blocks were abraded with 320 to 600-grit abrasive papers to obtain flat standardized dentin surfaces. G1 and G3 were Er:YAG irradiated. Blocks were immediately restored with 4-mm-high composite resin (Adper Single Bond 2, Z-250-3 M/ESPE). After 24 h, the restored blocks (n = 9) were serially sectioned and trimmed to an hour-glass shape of approximately 1 mm(2) at the bonded interface area, and tested in tension in a universal testing machine (1 mm/ min). Failure mode was determined at a magnification of 100x using a stereomicroscope. One block of each group was selected for scanning electron microscope (SEM) analysis. mu TBS data was analyzed by two-way ANOVA and Tukey test (alpha = 0.05). Mean bond strengths (SD) in MPa were: G1- 32.7 (5.9)(A); G2- 31.1 (6.3)(A); G3- 25.2 (8.3)(B); G4- 36.7 (9.9).(A) Groups with different uppercase letters were significantly different from each other (p < .05). Enamel bleaching procedure did not affect mu TBS values for dentin adhesion. Er:YAG laser irradiation with 25.56 J/cm(2) prior to adhesive procedure of bleached teeth did not affect mu TBS at dentin and promoted a dentin surface with no smear layer and opened dentin tubules observed under SEM. On the other hand, Er:YAG laser irradiation prior to adhesive procedure of non-bleached surface impaired mu TBS compared to the control group.

Identificador

LASERS IN MEDICAL SCIENCE, LONDON, v. 27, n. 1, supl. 1, Part 2, pp. 31-38, JAN, 2012

0268-8921

http://www.producao.usp.br/handle/BDPI/41456

10.1007/s10103-010-0838-1

http://dx.doi.org/10.1007/s10103-010-0838-1

Idioma(s)

eng

Publicador

SPRINGER LONDON LTD

LONDON

Relação

LASERS IN MEDICAL SCIENCE

Direitos

closedAccess

Copyright SPRINGER LONDON LTD

Palavras-Chave #ER:YAG LASER #SCANNING ELECTRON MICROSCOPE #MICROTENSILE BOND STRENGTH #BLEACHED DENTIN #ER-YAG-LASER #DIFFERENT ADHESIVE SYSTEMS #IRRADIATED HUMAN DENTIN #CARBAMIDE PEROXIDE #ERYAG LASER #IN-VITRO #ENAMEL MICROHARDNESS #ABLATION RATE #SEM ANALYSIS #BOVINE #ENGINEERING, BIOMEDICAL #SURGERY
Tipo

article

original article

publishedVersion