Resumo

1. 1. A polarographic method for the measurement of the available oxygen in the muscle of living carp by the use of a platinum microelectrode is proposed. 2. 2. The oxygen and the reference electrodes were assembled in a single insertion piece which was implanted in the muscle of a living carp maintained in a special experimental chamber. 3. 3. Curves for normal oxygen levels corresponding to air-saturated water, as well as to a carbogene-saturated water, were obtained. 4. 4. The method can be considered adequate for the measurement of tissue oxygen in living fishes. © 1984.

Formato

675-679

Identificador

http://dx.doi.org/10.1016/0300-9629(84)90615-7

Comparative Biochemistry and Physiology, Part A, v. 78, n. 4, p. 675-679, 1984.

1095-6433

1531-4332

http://hdl.handle.net/11449/132363

10.1016/0300-9629(84)90615-7

WOS:A1984TJ81800009

2-s2.0-0021119910

Idioma(s)

eng

Relação

Comparative Biochemistry and Physiology Part A: Physiology

Direitos

closedAccess

Palavras-Chave #Carbon dioxide #Fresh water #Sodium chloride #Animal #Carp #Cypriniformes #Electrode #Metabolism #Muscle #Oxygen consumption #pH #Polarography #Temperature #Animal #Carbon Dioxide #Carps #Cyprinidae #Electrodes, Implanted #Fresh Water #Hydrogen-Ion Concentration #Muscles #Oxygen Consumption #Polarography #Sodium Chloride #Support, Non-U.S. Gov't #Temperature
Tipo

info:eu-repo/semantics/article