Microhardness of glass ionomer cements indicated for the ART technique according to surface protection treatment and storage time
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
27/05/2014
27/05/2014
01/10/2009
|
Resumo |
The aim of this study was to assess the microhardness of 5 glass ionomer cements (GIC) - Vidrion R (V, SS White), Fuji IX (F, GC Corp.), Magic Glass ART (MG, Vigodent), Maxxion R (MR, FGM) and ChemFlex (CF, Dentsply) - in the presence or absence of a surface protection treatment, and after different storage periods. For each GIC, 36 test specimens were made, divided into 3 groups according to the surface protection treatment applied - no protection, varnish or nail varnish. The specimens were stored in distilled water for 24 h, 7 and 30 days and the microhardness tests were performed at these times. The data obtained were submitted to the ANOVA for repeated measures and Tukey tests (α = 5%). The results revealed that the mean microhardness values of the GICs were, in decreasing order, as follows: F > CF = MR > MG > V; that surface protection was significant for MR, at 24 h, without protection (64.2 ± 3.6a), protected with GIC varnish (59.6 ± 3.4b) and protected with nail varnish (62.7 ± 2.8ab); for F, at 7 days, without protection (97.8 ± 3.7ab), protected with varnish (95.9 ± 3.2b) and protected with nail varnish (100.8 ± 3.4a); and at 30 days, for F, without protection (98.8 ± 2.6b), protected with varnish (103.3 ± 4.4a) and protected with nail varnish (101 ± 4.1ab) and, for V, without protection (46 ± 1.3b), protected with varnish (49.6 ± 1.7ab) and protected with nail varnish (51.1 ± 2.6a). The increase in storage time produced an increase in microhardness. It was concluded that the different GICs, surface protection treatments and storage times could alter the microhardness values. |
Formato |
439-445 |
Identificador |
http://dx.doi.org/10.1590/S1806-83242009000400014 Brazilian Oral Research, v. 23, n. 4, p. 439-445, 2009. 1806-8324 1807-3107 http://hdl.handle.net/11449/71186 10.1590/S1806-83242009000400014 S1806-83242009000400014 2-s2.0-77953721359 2-s2.0-77953721359.pdf |
Idioma(s) |
eng |
Relação |
Brazilian Oral Research |
Direitos |
openAccess |
Palavras-Chave | #Cavity #Glass ionomer cements #Hardness tests #Varnish #glass ionomer #analysis of variance #atraumatic restorative treatment #chemistry #dental surgery #drug storage #hardness #instrumentation #materials testing #methodology #surface property #time #Analysis of Variance #Dental Atraumatic Restorative Treatment #Dental Cavity Lining #Drug Storage #Glass Ionomer Cements #Hardness Tests #Materials Testing #Surface Properties #Time Factors |
Tipo |
info:eu-repo/semantics/article |