ADJUSTED F FACTOR FOR MULTIPLE-OUTLET PIPES.


Autoria(s): Scaloppi, Edmar José
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

27/05/2014

27/05/2014

01/02/1988

Resumo

An adjusted F factor to compute pressure head loss in pipes having multiple, equally spaced outlets is derived for any given distance from the first outlet to the beginning of the pipe. The proposed factor is dependent on the number of outlets and is expressed as a function of the J. E. Christiansen's F factor. It may be useful to irrigation engineers to estimate friction in sprinkle and trickle irrigation laterals and manifolds, as well as gated pipes.

Formato

169-174

Identificador

http://dx.doi.org/10.1061/(ASCE)0733-9437(1988)114:1(169)

Journal of Irrigation and Drainage Engineering, v. 114, n. 1, p. 169-174, 1988.

0733-9437

http://hdl.handle.net/11449/63848

10.1061/(ASCE)0733-9437(1988)114:1(169)

2-s2.0-0023797523

2-s2.0-0023797523.pdf

Idioma(s)

eng

Relação

Journal of Irrigation and Drainage Engineering

Direitos

openAccess

Palavras-Chave #FRICTION #HYDRAULICS - Analysis #IRRIGATION #PRESSURE EFFECTS #F FACTOR #MULTIPLE-OUTLET PIPES #FLOW OF WATER
Tipo

info:eu-repo/semantics/article