Coronary perfusion pressure as a determinant of ventricular performance


Autoria(s): Tucci, P. J. F.; Spadaro, J.; Ciogna, A. C.; Bregagnollo, E. A.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

26/05/2014

26/05/2014

01/12/1980

Resumo

The results observed in this work support the view that coronary perfusion pressure affects ventricular performance independently of metabolic effects; a mechanism operating in beat-to-beat regulation is proposed.