Resumo

The aim of this work was the development of miniaturized structures useful for retention and/or selection of particles and viscous substances from a liquid flow. The proposed low costs structures are similar to macroscopic wastewater treatment systems, named baffles, and allow disassemble. They were simulated using FEMLAB 3.2b package and manufactured in acrylic with conventional tools. Tests for retention or selection of particles in water or air and viscous fluids in water were carried out. Either in air or water particles with 50 mu m diameter will be retained but not with 13 mu m diameter. In aqueous flow, it is also possible the retention of viscous samples, such as silicone 350 cSt. The simulated results showed good agreement with experimental measurements. These miniaturized structures can be useful in sample pretreatment for chemical analysis and microorganism manipulation. (C) 2007 Elsevier B.V. All rights reserved.

Formato

310-319

Identificador

http://dx.doi.org/10.1016/j.snb.2007.08.014

Sensors and Actuators B-chemical. Lausanne: Elsevier B.V. Sa, v. 130, n. 1, p. 310-319, 2008.

0925-4005

http://hdl.handle.net/11449/41838

10.1016/j.snb.2007.08.014

WOS:000254681900046

Idioma(s)

eng

Publicador

Elsevier B.V. Sa

Relação

Sensors and Actuators B: Chemical

Direitos

closedAccess

Palavras-Chave #miniaturization #square wave mixer #simulation #particle retention #viscous material removal
Tipo

info:eu-repo/semantics/article