Determinação de carbaril utilizando testes ELISA (Enzyme-linked immunosorbent assay) e CLAE com detecção por arranjo de diodos
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
20/05/2014
20/05/2014
01/08/2000
|
Resumo |
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) ELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration ( ³30 mg L-1) and acidic pH conditions (pH 4.0) interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed. |
Formato |
466-471 |
Identificador |
http://dx.doi.org/10.1590/S0100-40422000000400007 Química Nova. Sociedade Brasileira de Química, v. 23, n. 4, p. 466-471, 2000. 0100-4042 http://hdl.handle.net/11449/27569 10.1590/S0100-40422000000400007 S0100-40422000000400007 S0100-40422000000400007.pdf |
Idioma(s) |
por |
Publicador |
Sociedade Brasileira de Química |
Relação |
Química Nova |
Direitos |
openAccess |
Palavras-Chave | #ELISA #carbaryl #fulvic acids |
Tipo |
info:eu-repo/semantics/article |