Kinetic model of poly(3-hydroxybutyrate) thermal degradation from experimental non-isothermal data


Autoria(s): Santos, A. F.; Polese, L.; Crespi, Marisa Spirandeli; Ribeiro, Clovis Augusto
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/04/2009

Resumo

The non-isothermal data given by TG curves for poly(3-hydroxybutyrate) (PHB) were studied in order to obtain a consistent kinetic model that better represents the PHB thermal decomposition. Thus, data obtained from the dynamic TG curves were suitably managed in order to obtain the Arrhenius kinetic parameter E according to the isoconversional F-W-O method. Once the E parameters is found, a suitable logA and kinetic model (f(alpha)) could be calculated. Hence, the kinetic triplet (E +/- SD, logA +/- SD and f(alpha)) obtained for the thermal decomposition of PHB under non-isothermal conditions was E=152 +/- 4 kJ mol(-1), logA=14.1 +/- 0.2 s(-1) for the kinetic model, and the autocatalytic model function was: f(alpha)=alpha(m)(1-alpha)(n)=alpha(0.42)(1-alpha)(0.56).

Formato

287-291

Identificador

http://dx.doi.org/10.1007/s10973-006-8208-8

Journal of Thermal Analysis and Calorimetry. Dordrecht: Springer, v. 96, n. 1, p. 287-291, 2009.

1388-6150

http://hdl.handle.net/11449/25841

10.1007/s10973-006-8208-8

WOS:000264133900044

Idioma(s)

eng

Publicador

Springer

Relação

Journal of Thermal Analysis and Calorimetry

Direitos

closedAccess

Palavras-Chave #biodegradable polymers #non-isothermal kinetic #PHB thermal degradation
Tipo

info:eu-repo/semantics/article