Estudo do biomaterial Ti-6Al-4V empregando-se técnicas eletroquímicas e XPS


Autoria(s): Ramires, Ivan; Guastaldi, Antonio Carlos
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/02/2002

Resumo

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

The Ti-6Al-4V alloy used as biomaterial has been used over the last years. The literature shows controversies concerning the kind and the chemical composition of the film naturally and elctrochemically formed on the surface of the titanium alloy. The presente work studies the film composition before and after the electrochemical polarization tests using the x Ray photoelectron spectroscopy (XPS) technique. The results showed that the film naturally formed on the metallic surface is constituted of a variety of oxides which do not cover the whole surface of the metallic alloy and therefore, metallic Ti, Al and V can be found on the uncovered areas. The tests of XPS made after the polarization up to 4V (SCE) showed that the electrochemically formed film is constituted only of TiO2 and that the peak current observed around 1,5 V (SCE) is due to the oxidation of any kind of titanium oxide or the growth of the film.

Formato

10-14

Identificador

http://dx.doi.org/10.1590/S0100-40422002000100003

Química Nova. Sociedade Brasileira de Química, v. 25, n. 1, p. 10-14, 2002.

0100-4042

http://hdl.handle.net/11449/25468

10.1590/S0100-40422002000100003

S0100-40422002000100003

S0100-40422002000100003.pdf

Idioma(s)

por

Publicador

Sociedade Brasileira de Química

Relação

Química Nova

Direitos

openAccess

Palavras-Chave #titanium #corrosion #XPS #TiO2
Tipo

info:eu-repo/semantics/article