Detection of respiratory paradoxical movement via doppler radar measurements


Autoria(s): Lee,YS; Pathirana,PN; Steinfort,C
Data(s)

01/01/2014

Resumo

 This paper presents an evaluation of microwave Doppler radar in capturing the respiration signal from the chest and abdomen simultaneously using two radar systems. Two experiments were conducted to investigate the feasibility of using Doppler radar in measuring respiration from both chest and abdomen simultaneously. Results obtained indicate that the respiration patterns from the radar were highly correlated with the reference respiration strap readings for normal breathing scenarios and also sensitive enough in capturing the paradoxical movement between the chest and the abdomen in the professionally role played experiments.

Identificador

http://hdl.handle.net/10536/DRO/DU:30071914

Idioma(s)

eng

Publicador

IEEE

Relação

http://dro.deakin.edu.au/eserv/DU:30071914/lee-detectionofrespiratory-2014.pdf

http://dro.deakin.edu.au/eserv/DU:30071914/lee-detectionofrespiratory-evid-2014.pdf

http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=7057698

Direitos

2014, IEEE

Tipo

Conference Paper