Evaluating OSHA's ethylene oxide standard: employer exposure-monitoring activities in Massachusetts hospitals from 1985 through 1993


Autoria(s): LaMontagne, Anthony D.; Kelsey, Karl T.
Data(s)

01/01/1997

Resumo

This study characterized exposure-monitoring activities and findings under the Occupational Safety and Health Administration's (OSHA's) 1984 ethylene oxide (EtO) standard. In-depth mail and telephone surveys were followed by on-site interviews at all EtO-using hospitals in Massachusetts (n = 92, 96% participation rate). By 1993, most hospitals had performed personal exposure monitoring for OSHA's 8-hour action level (95%) and the excursion limit (87%), although most did not meet the 1985 implementation deadline. In 1993, 66% of hospitals reported the installation of EtO alarms to fulfill the standard's "alert" requirement. Alarm installation also lagged behind the 1985 deadline and peaked following a series of EtO citations by OSHA. From 1990 through 1992, 23% of hospitals reported having exceeded the action level once or more; 24% reported having exceeded the excursion limit; and 33% reported that workers were accidentally exposed to EtO in the absence of personal monitoring. Almost a decade after passage of the EtO standard, exposure-monitoring requirements were widely, but not completely, implemented. Work-shift exposures had markedly decreased since the mid-1980s, but overexposures continued to occur widely. OSHA enforcement appears to have stimulated implementation.

Identificador

http://hdl.handle.net/10536/DRO/DU:30065777

Idioma(s)

eng

Publicador

American Public Health Association

Relação

http://dro.deakin.edu.au/eserv/DU:30065777/lamontagne-activitiesmassachusetts-1997.pdf

http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1380884/

Tipo

Journal Article