Simulation and evaluation of HERIC and H5 transformerless inverter topologies


Autoria(s): Alzoubi, Muh'd; Amanullah, Maung Than Oo; Azad, Salahuddin
Contribuinte(s)

Kaitwanidvilai, S.

Data(s)

01/01/2013

Resumo

Most of the inverters have an isolation transformer which prevents or limits fault current between AC and DC circuits under most fault conditions. If the transformer is excluded from the system, it would increase the PV system efficiency and decrease the size of its installations, which will lead to a lower cost for the whole investment. Thus, elimination of the transformer has to be considered carefully because a galvanic connection appears between the PV arrays and the ground in the absence of an isolation transformer. The galvanic connection causes the stray capacitance between the PV arrays structure and the ground to produce a leakage current. In this paper, a review of full bridge topology with bipolar and unipolar scheme and half bridge topology carried out in regard leakage current.in addition, HERIC and H5 topologies are simulated and leakage current in these topologies are evaluated.

Identificador

http://hdl.handle.net/10536/DRO/DU:30063356

Idioma(s)

eng

Publicador

ACTA Press

Relação

http://dro.deakin.edu.au/eserv/DU:30063356/maungthanoo-simulation-evid1-2013.pdf

http://dro.deakin.edu.au/eserv/DU:30063356/maungthanoo-simulation-evid2-2013.pdf

http://dro.deakin.edu.au/eserv/DU:30063356/maungthanoo-simulation-evid3-2013.pdf

http://dro.deakin.edu.au/eserv/DU:30063356/maungthanoo-simulationand-2013.pdf

http://doi.org/10.2316/P.2013.800-101

Palavras-Chave #transformeless inverter #leakage current #simulation #HERIC #H5 full bridge modulation
Tipo

Conference Paper