Simulation of three-point bending test of titanium foam for biomedical applications


Autoria(s): Kashef, Sadaf; Asgari, Alireza; Hodgson, Peter; Yan, Wenyi
Data(s)

01/01/2008

Resumo

Using Titanium (Ti) foam as an implant material is a new approach for biomedical applications and it is important to understand the mechanical behaviors of this new foam material. In the present study, the bending of the Ti foam has been simulated and compared against recently published data [1]. FE Analysis has been performed by Abaqus software. Stiffness and Yield strength of foams between 50% (cortical bone) to 80% (cancellous bone) porosity range were considered. This study showed that crushable foam material model in Abaqus, which has developed primarily for Aluminum (Al) foam alloys, is also valid for Ti Foam before any crack or damage occurs in the sample.

Identificador

http://hdl.handle.net/10536/DRO/DU:30017262

Idioma(s)

eng

Publicador

Trans Tech

Relação

http://dro.deakin.edu.au/eserv/DU:30017262/kashef-simulationofthreepoint-2008.pdf

http://dx.doi.org/10.4028/www.scientific.net/AMR.32.237

Palavras-Chave #titanium foam #bending #finite element modeling
Tipo

Journal Article