Degree of Conversion and Temperature Increase of a Composite Resin Light Cured with an Argon Laser and Blue LED
Contribuinte(s) |
UNIVERSIDADE DE SÃO PAULO |
---|---|
Data(s) |
20/10/2012
20/10/2012
2008
|
Resumo |
Different light sources and power densities used on the photoactivation process may provide changes in the degree of conversion (DC%) and temperature ( T) of the composite resins. Thus, the purpose of this study was to evaluate the DC (%) and T (degrees C) of the microhybrid composite resin (Filtek (TM) Z-250, 3M/ESPE) photoactivated with one argon laser and one LED (light-emitting diode) with different power densities. For the KBr pellet technique, the composite resin was placed into a metallic mould (2-mm thickness, 4-mm diameter) and photoactivated as follows: a continuous argon laser (CW) and LED LCUs with power density values of 100, 400, 700, and 1000 mW/cm(2) for 20 s. The measurements for DC (%) were made in a FTIR spectrometer Bomen ( model MB 102, Quebec, Canada). Spectroscopy ( FTIR) spectra for both uncured and cured samples were analyzed using an accessory of the reflectance diffusion. The measurements were recorded in absorbance operating under the following conditions: 32 scans, 4 cm(-1) resolution, 300 to 4000-cm(-1) wavelength. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1638 cm(-1)) against an internal standard before and after the curing of the specimen: aromatic C-C (peak at 1608 cm(-1)). For T (degrees C), the samples were created in a metallic mould (2-mm thickness, 4-mm diameter) and photoactivated for 20 s. The thermocouple was attached to the multimeter allowing temperature readings. The DC (%) and T (degrees C) were submitted to ANOVA and Tukey`s test (p < 0.05). The degree of conversion values varied from 35.0 to 50.0% ( 100 to 1000 mW/cm(2)) for an argon laser and from 41.0 to 49% (100 to 1000 mW/cm(2)) for an LED. The temperature change values varied from 1.1 to 13.1 degrees C (100 to 1000 mW/cm(2)) for an argon laser and from 1.9 to 15.0 degrees C (100 to 1000 mW/cm(2)) for an LED. The power densities showed a significant effect on the degree of conversion and changes the temperature for both light-curing units. Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) FAPESP Fundacao de Amparo Pesquisa do Estado de Sao Paulo, SP, Brazil |
Identificador |
LASER PHYSICS, v.18, n.12, p.1570-1575, 2008 1054-660X http://producao.usp.br/handle/BDPI/29753 10.1134/S1054660X0812030X |
Idioma(s) |
eng |
Publicador |
MAIK NAUKA/INTERPERIODICA/SPRINGER |
Relação |
Laser Physics |
Direitos |
restrictedAccess Copyright MAIK NAUKA/INTERPERIODICA/SPRINGER |
Palavras-Chave | #MECHANICAL-PROPERTIES #CONVENTIONAL LIGHT #BOND STRENGTH #POLYMERIZATION #HALOGEN #RESTORATIONS #TECHNOLOGY #DEPTH #HEAT #RISE #Optics #Physics, Applied |
Tipo |
article original article publishedVersion |