Effect of blood contamination on the shear bond strength at resin/dentin interface in primary teeth


Autoria(s): RAFFAINI, Maria Stella; GOMES-SILVA, Jaciara Miranda; TORRES-MANTOVANI, Carolina Paes; PALMA-DIBB, Regina Guenka; BORSATTO, Maria Cristina
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2008

Resumo

Purpose: To assess in vitro the shear bond strength at the resin/dentin interface in primary teeth after contamination with fresh human blood. Methods: 75 crowns of primary molars were embedded in acrylic resin and mechanically ground to expose a flat dentin surface. The specimens were randomly assigned to five groups (n=15), according to the surface treatment. Group I (control) had no blood contamination. The other groups were blood-contaminated and subjected to different post-contamination protocols: in Group 2, the surfaces were rinsed with water; in Group 3, the surfaces were air-dried; in Group 4, the surfaces were rinsed and air-dried; and in Group 5, no post-contamination treatment was done. In all groups, a 3-mm dentin bonding site was demarcated, Single Bond adhesive system was applied and resin composite cylinders were bonded. After 24 hours in distilled water, shear bond strength was tested at a crosshead speed of 0.5 mm/minute. Results: Means (in MPa) were: Group 1: 7.1 (+/- 4.2); Group 2: 4.0 (+/- 1.8); Group 3: 0.9 (+/- 0.7); Group 4: 3.9 (+/- 2.2) and Group 5: 1.3 (+/- 1.5). Data were analyzed statistically by the Kruskal-Wallis test at 5% significance level. Groups 2 and 4 were similar to each other (P > 0.05) and both ware similar to Group 1 (P > 0.05). These groups (2, 3 and 4) had statistically significantly higher bond strengths than Groups 3 and 5 (P < 0.05). Blood contamination negatively affected the shear bond strength to primary tooth dentin. Among the blood-contaminated groups, water-rinsed specimens had higher bond strengths than those that were exclusively air-dried or not submitted to any post-contamination protocol before adhesive application.

Identificador

AMERICAN JOURNAL OF DENTISTRY, v.21, n.3, p.159-162, 2008

0894-8275

http://producao.usp.br/handle/BDPI/26446

http://apps.isiknowledge.com/InboundService.do?Func=Frame&product=WOS&action=retrieve&SrcApp=EndNote&UT=000257764700005&Init=Yes&SrcAuth=ResearchSoft&mode=FullRecord

Idioma(s)

eng

Publicador

MOSHER & LINDER, INC

Relação

American Journal of Dentistry

Direitos

closedAccess

Copyright MOSHER & LINDER, INC

Palavras-Chave #CARIES-AFFECTED DENTIN #ADHESIVE SYSTEMS #BOTTLE ADHESIVES #RESIN #BRACKETS #ENAMEL #SALIVA #WATER #Dentistry, Oral Surgery & Medicine
Tipo

article

original article

publishedVersion