Heating control of an electrical motor


Autoria(s): Murashko, Kirill
Data(s)

03/08/2010

03/08/2010

2010

Resumo

Electrical motors on a ship attackable to different factors which decrease these lifetimes. One of the main external factors on a ship which usually is a reason of the motor failure is a moisture condensation which decreases the motor winding insulation and increase a probability of the short circuit. Therefore, the protection against moisture is necessary for ship electrical motors. The motor should be protected against moisture all time when it does not operate. The necessity of such protection requires a lot of energy consumption. This master’s thesis is focused on the creation of the electrical motor thermal model and on the different methods of the motor protection against moisture analysis with energy consumption point of view.

Identificador

http://www.doria.fi/handle/10024/63249

Idioma(s)

en

Palavras-Chave #DC and AC heating #electricalmotor thermal model #Trickle Voltage Heating #Heaters #Ship electrical motor protection
Tipo

Master's thesis

Diplomityö