Série histórica da composição química de pilhas alcalinas e zinco-carbono fabricadas entre 1991 e 2009


Autoria(s): Silva,Bruno Oliveira da; Câmara,Sílvio Carrielo; Afonso,Júlio Carlos; Neumanne,Reiner; Alcover Neto,Arnaldo
Data(s)

01/01/2011

Resumo

Mn, Zn, Fe, Cd, Pb and Hg were determined in Zn-C and alkaline batteries manufactured along almost 20 years. After samples disassembly the electroactive components were treated with aqua regia in bath ice for 24 h. Metals were analyzed by ICP-OES. Zn and Mn amounts did not vary significantly. Fe amount decreased, specially after 2000. Hg, Cd and Pb amounts dramatically decreased along time, being virtually absent in alkaline batteries manufactured after 2005. Pb still remains in Zn-C samples. Scanning electron microscopy of batteries manufactured in 1997 and 1998 showed the presence of Bi, In and Cr in the plastic/paper anode-cathode separator.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000500016

Idioma(s)

pt

Publicador

Sociedade Brasileira de Química

Fonte

Química Nova v.34 n.5 2011

Palavras-Chave #batteries #chemical composition #heavy metals
Tipo