Exporting Contours to DICOM-RT Structure Set
Data(s) |
2009
|
---|---|
Resumo |
This paper presents an ITK implementation for exportingthe contours of the automated segmentation results toDICOM-RT Structure Set format. The âeurooeradiotherapystructure setâeuro (RTSTRUCT) object of the DICOM standard isused for the transfer of patient structures and relateddata, between the devices found within and outside theradiotherapy department. It mainly contains theinformation of regions of interest (ROIs) and points ofinterest (E.g. dose reference points). In many cases,rather than manually drawing these ROIs on the CT images,one can indeed benefit from the automated segmentationalgorithms already implemented in ITK. But at present, itis not possible to export the ROIs obtained from ITK toRTSTRUCT format. In order to bridge this gap, we havedeveloped a framework for exporting contour data toRTSTRUCT. We provide here the complete implementation ofRTSTRUCT exporter and present the details of the pipelineused. Results on a 3-D CT image of the Head and Neck(H&N) region are presented. |
Identificador |
http://serval.unil.ch/?id=serval:BIB_A1376BE3F444 http://www.insight-journal.org/ http://my.unil.ch/serval/document/BIB_A1376BE3F444.pdf http://nbn-resolving.org/urn/resolver.pl?urn=urn:nbn:ch:serval-BIB_A1376BE3F4449 |
Idioma(s) |
en |
Direitos |
info:eu-repo/semantics/openAccess |
Fonte |
Insight Journal, no. 1, pp. 1-18 |
Palavras-Chave | #DICOM-RT; RTSTRUCT; Radiotherapy; ITK; GDCM |
Tipo |
info:eu-repo/semantics/article article |