Modelling the cooling of concrete by piped water
Contribuinte(s) |
Centre de Recerca Matemàtica |
---|---|
Data(s) |
01/01/2010
|
Resumo |
Piped water is used to remove hydration heat from concrete blocks during construction. In this paper we develop an approximate model for this process. The problem reduces to solving a one-dimensional heat equation in the concrete, coupled with a first order differential equation for the water temperature. Numerical results are presented and the effect of varying model parameters shown. An analytical solution is also provided for a steady-state constant heat generationmodel. This helps highlight the dependence on certain parameters and can therefore provide an aid in the design of cooling systems. |
Formato |
22 211946 bytes application/pdf |
Identificador | |
Idioma(s) |
eng |
Publicador |
Centre de Recerca Matemàtica |
Relação |
Prepublicacions del Centre de Recerca Matemàtica;921 |
Direitos |
Aquest document està subjecte a una llicència d'ús de Creative Commons, amb la qual es permet copiar, distribuir i comunicar públicament l'obra sempre que se'n citin l'autor original, la universitat i el centre i no se'n faci cap ús comercial ni obra derivada, tal com queda estipulat en la llicència d'ús (http://creativecommons.org/licenses/by-nc-nd/2.5/es/) |
Palavras-Chave | #Temperatura #Models matemàtics #Anàlisi tèrmica #54 - Química |
Tipo |
info:eu-repo/semantics/preprint |