Hepatitis B vaccine - proposal for a standardized assessment of immune response
Data(s) |
01/04/1992
|
---|---|
Resumo |
The authors developed a comparative study of the various methods of assessment of immune response to Hepatitis B vaccine. Eighty-six health care professionals underwent a vaccination programme with three doses of plasma-derived vaccine against Hepatitis B (H-B-Vax, Merck, Sharp & Dohme) given intra-muscularly. Assessment of immune response was carried out three months after the end of the programme, by radioimmunoassay (RIA) and enzymeimmunoassay (EIA). The results showed that the semi-quantitative assessment of Anti-HBs antibodies by RIA or EIA was perfectly comparable to the reference method (quantitative determination of antibodies by RIA). In view of these findings, the authors suggest a standardization of assessment of immune response to the vaccine, thus permitting correct planning of booster doses and easier comparison between different studies |
Formato |
text/html |
Identificador |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0036-46651992000200009 |
Idioma(s) |
en |
Publicador |
Instituto de Medicina Tropical |
Fonte |
Revista do Instituto de Medicina Tropical de São Paulo v.34 n.2 1992 |
Palavras-Chave | #Hepatitis B #Hepatitis B Vaccine #Anti-HBS #Antibodies |
Tipo |
journal article |