A titrimetric respirometer measuring the nitrifiable nitrogen in wastewater using in-sensor-experiment


Autoria(s): Yuan, Z. G.; Bogaert, H.
Contribuinte(s)

Wilderer.P

Data(s)

01/01/2001

Resumo

Measurement of nitrifiable nitrogen contained in wastewater by combining the existing respirometric and titrimetric principles is reported. During an in-sensor-experiment using nitrifying activated sludge. both the dissolved oxygen (DO) and pH in the mixed liquor were measured, and the FH was controlled at a set-point through titration of base or acid. A combination of the oxygen uptake rate (OUR), which was obtained from the measured DO signal, and the titration data allowed calculation of the nitrifiable nitrogen and the short-term biological oxygen demand (BOD) of the wastewater sample that was initially added to the sludge. The calculation was based solely on stoichiometric relationships. The approach was preliminarily tested with two types of wastewaters using a prototype sensor. Good correlation was obtained. (C) 2000 Elsevier Science Ltd. All rights reserved.

Identificador

http://espace.library.uq.edu.au/view/UQ:59311

Idioma(s)

eng

Publicador

Elsevier Science Ltd

Palavras-Chave #Activated Sludge #Nitrifiable Nitrogrn #In-sensor-experiment #Repirometry #Titrimetry #On-line Measurement #Engineering, Environmental #Environmental Sciences #Water Resources #Nitrifiable Nitrogen #Respirometry #Activated-sludge #Nitrification #Model #Water #C1 #770502 Land and water management #291101 Environmental Engineering Modelling
Tipo

Journal Article