Ventilation Distribution Studies Comparing Technegas and ""Gallgas"" Using (68)GaCl(3) as the Label


Autoria(s): BORGES, Joao Batista; VELIKYAN, Irina; LANGSTROM, Bengt; SORENSEN, Jens; ULIN, Johan; MARIPUU, Enn; SANDSTROM, Mattias; WIDSTROM, Charles; HEDENSTIERNA, Goran
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2011

Resumo

Ventilation distribution can be assessed by SPECT with Technegas. This study was undertaken in piglets with different degrees of ventilation inhomogeneity to compare PET using (68)Ga-labeled pseudogas or ""Gallgas"" with Technegas. Methods: Twelve piglets were studied in 3 groups: control, lobar obstruction, and diffuse airway obstruction. Two more piglets were assessed for lung volume (functional residual capacity). Results: In controls, SPECT and PET images showed an even distribution of radioactivity. With lobar obstruction, the absence of ventilation of the obstructed lobe was visible with both techniques. In diffuse airway obstruction, SPECT images showed an even distribution of radioactivity, and PET images showed more varied radioactivity over the lung. Conclusion: PET provides detailed ventilation distribution images and a better appreciation of ventilation heterogeneity. Gallgas with PET is a promising new diagnostic tool for the assessment of ventilation distribution.

Uppsala University

Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)-Ministry of Education, Brazil

GE Healthcare

Identificador

JOURNAL OF NUCLEAR MEDICINE, v.52, n.2, p.206-209, 2011

0161-5505

http://producao.usp.br/handle/BDPI/22859

10.2967/jnumed.110.083881

http://dx.doi.org/10.2967/jnumed.110.083881

Idioma(s)

eng

Publicador

SOC NUCLEAR MEDICINE INC

Relação

Journal of Nuclear Medicine

Direitos

restrictedAccess

Copyright SOC NUCLEAR MEDICINE INC

Palavras-Chave #ventilation #Technegas #SPECT #(68)Ga-pseudogas #PET #AIRWAY #MUSCLE #CT #Radiology, Nuclear Medicine & Medical Imaging
Tipo

article

original article

publishedVersion