Resumo |
This paper analyzes the behavior of the base of a precast column in the socket foundation with smooth interfaces. This research is motivated by the lack of information and guidelines on the behavior of column bases in the embedded region. An experimental program with two full-scale specimens was carried-out. These two specimens had smooth interfaces at the internal faces of the socket, different embedded lengths and were subjected to loads with large eccentricities. The experimental results showed that the failure of the specimens occurred by the yielding of the longitudinal reinforcement out of the embedded region, while the transverse reinforcement was not very stressed. Some recommendations on the anchorage of the longitudinal reinforcement and a strut-and-tie model for the behavior of column bases in the embedded region are proposed. CNPq FAPESP |
Identificador |
MATERIALS AND STRUCTURES, v.42, n.6, p.725-737, 2009 1359-5997 http://producao.usp.br/handle/BDPI/17875 10.1617/s11527-008-9416-4 |
Idioma(s) |
eng |
Publicador |
SPRINGER |
Relação |
Materials and Structures |
Direitos |
restrictedAccess Copyright SPRINGER |
Palavras-Chave | #Columns base #Socket foundation #Smooth interfaces #Connection #Precast concrete #Construction & Building Technology #Engineering, Civil #Materials Science, Multidisciplinary |