Effects of elevated temperatures on bolted moment-connections between cold-formed steel members
Data(s) |
01/10/2007
|
---|---|
Resumo |
Experimental investigations at ambient temperature into the behaviour of bolted moment-connections between cold-formed steel members have previously been described. Full-scale joint tests have demonstrated that the channel-sections being connected are susceptible to premature failure, the result of web buckling caused by the concentration of load transfer from the bolts. The results of tests on bolted lap joints have been used to propose design recommendations for the shear strength in bearing of the bolt-hole. For both types of test, the results of non-linear elasto-plastic finite element analyses have been shown to have good agreement. No consideration, however, has been given to the behaviour of such connections at elevated temperatures. This paper describes non-linear elasto-plastic finite element parametric studies into the effects of elevated temperatures on bolted moment-connections between cold-formed steel members. Two issues at elevated temperatures are investigated: |
Identificador | |
Idioma(s) |
eng |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Lim , J & Young , B 2007 , ' Effects of elevated temperatures on bolted moment-connections between cold-formed steel members ' Engineering Structures , vol 29 , no. 10 , pp. 2419-2427 . DOI: 10.1016/j.engstruct.2006.11.027 |
Palavras-Chave | #/dk/atira/pure/subjectarea/asjc/2200/2205 #Civil and Structural Engineering |
Tipo |
article |