Modelling and Prediction of NOx Emission in a Coal-Fired Power Generation Plant
Data(s) |
01/06/2004
|
---|---|
Resumo |
In this paper NOx emissions modelling for real-time operation and control of a 200 MWe coal-fired power generation plant is studied. Three model types are compared. For the first model the fundamentals governing the NOx formation mechanisms and a system identification technique are used to develop a grey-box model. Then a linear AutoRegressive model with eXogenous inputs (ARX) model and a non-linear ARX model (NARX) are built. Operation plant data is used for modelling and validation. Model cross-validation tests show that the developed grey-box model is able to consistently produce better overall long-term prediction performance than the other two models. |
Identificador |
http://dx.doi.org/10.1016/S0967-0661(03)00171-0 http://www.scopus.com/inward/record.url?scp=2342644856&partnerID=8YFLogxK |
Idioma(s) |
eng |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Li , K , Peng , J X & Thompson , S 2004 , ' Modelling and Prediction of NOx Emission in a Coal-Fired Power Generation Plant ' Control Engineering Practice , vol 12(6) , no. 6 , pp. 707-723 . DOI: 10.1016/S0967-0661(03)00171-0 |
Palavras-Chave | #/dk/atira/pure/subjectarea/asjc/2200/2207 #Control and Systems Engineering #/dk/atira/pure/subjectarea/asjc/2200/2209 #Industrial and Manufacturing Engineering |
Tipo |