High sensitivity beam phase measurement system for isochronous cyclotron
Data(s) |
3914
|
---|---|
Resumo |
The beam phase measurement system in the HIRFL is introduced. Based on the double-balanced mixer principle using rf-signal mixing and filtering techniques, a stable and sensitive phase measurement system has been developed. The phase history of the ion beam is detected by using a set of capacitive pick-up probes installed in the cyclotron. The phase information of the measurement is necessary for tuning to obtain a optimized isochronous magnetic field which induces to maximize the beam intensity and to optimize the beam quality. The result of the phase measurement is reliable and the accurancy reaches +/- 0.5 degrees. |
Identificador | |
Idioma(s) |
中文 |
Fonte |
Zheng, JH (Zheng Jian-Hua); Liu, W (Liu Wei); Wang, YF (Wang Yi-Fang); Wang, YM (Wang Yan-Mou); Ma, WN (Ma Wei-Nian); Yin, Y (Yin Yan); Song, HH (Song Hai-Hong).High sensitivity beam phase measurement system for isochronous cyclotron,HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION ,39142,31(3): 303-306 |
Palavras-Chave | #HIRFL #phase measurement #mixer and filter #isochronism of magnetic field #beam quality |
Tipo |
期刊论文 |