Fiber Bragg grating pressure sensor with ultrahigh sensitivity and reduced temperature sensitivity


Autoria(s): Zhang WT; Li F; Liu YL
Data(s)

2009

Resumo

A fiber Bragg grating (FBG) pressure sensing scheme based on a flat diaphragm and an L-shaped lever is presented. An L-shaped lever transfers the pressure-induced defection of the flat diaphragm to the axial elongation of the FBG. The curve where the L-shaped lever contacts the diaphragm is a segment of an Archimedes spiral, which is used to enhance the responsivity. Because the thermal expansion coefficient of the quartz-glass L-shaped lever and the steel sensor shell is different, the temperature effect is compensated for by optimizing the dimension parameters. Theoretical analysis is presented, and the experimental results show that an ultrahigh pressure responsivity of 244 pm/kPa and a low temperature responsivity of 2.8 pm/degrees C are achieved. (c) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI 10.1117/1.3081058]

Chinese Academy of Sciences CXJJ-177 This work was supported by the Key Projects Program of the Chinese Academy of Sciences under grant number CXJJ-177.

Identificador

http://ir.semi.ac.cn/handle/172111/7299

http://www.irgrid.ac.cn/handle/1471x/63387

Idioma(s)

英语

Fonte

Zhang WT ; Li F ; Liu YL .Fiber Bragg grating pressure sensor with ultrahigh sensitivity and reduced temperature sensitivity ,OPTICAL ENGINEERING,2009 ,48(2):Art. No. 024402

Palavras-Chave #光电子学 #pressure sensor #fiber Bragg grating #diaphragm
Tipo

期刊论文