Highly stable, diode-pumped Nd : YLF regenerative amplifier


Autoria(s): Wang Jiang-Feng; Li Xue-Chun; Wei Hui; 朱健强
Data(s)

2008

Resumo

We present the design and experimental results for a diode pumped Nd:YLF regenerative amplifier applied to amplify a nanosecond laser pulse. Numerical simulation shows that the maximum output energy and the best stability can be obtained when the regenerative amplifier operates in a saturated mode for all pulse duration and temporal profiles. Using extra post-pulse is a good method to decrease the square-pulse distortion caused by gain saturation effect. The amplifier shows output energy of 4.2mJ with a total energy gain of more than 107 and output energy stability of better than 1% rms. When extra post-pulse is added, square-pulse distortion is decreased from 1.33 to 1.17 for the amplifier that is seeded with an optical pulse of 3 ns.

Identificador

http://ir.siom.ac.cn/handle/181231/3230

http://www.irgrid.ac.cn/handle/1471x/10959

Idioma(s)

英语

Fonte

Wang Jiang-Feng;Li Xue-Chun;Wei Hui;朱健强.,Chin. Phys. Lett.,2008,25(2):524-527

Palavras-Chave #AMPLIFICATION #PULSES
Tipo

期刊论文