Experimental Investigation On The Holdup Distribution Of Oil-Water Two-Phase Flow In Horizontal Parallel Tubes
Data(s) |
2008
|
---|---|
Resumo |
An experimental investigation was conducted to study the holdup distribution of oil and water two-phase flow in two parallel tubes with unequal tube diameter. Tests were performed using white oil (of viscosity 52 mPa s and density 860 kg/m(3)) and tap water as liquid phases at room temperature and atmospheric outlet pressure. Measurements were taken of water flow rates from 0.5 to 12.5 m(3)/h and input oil volume fractions from 3 to 94 %. Results showed that there were different flow pattern maps between the run and bypass tubes when oil-water two-phase flow is found in the parallel tubes. At low input fluid flow rates, a large deviation could be found on the average oil holdup between the bypass and the run tubes. However, with increased input oil fraction at constant water flow rate, the holdup at the bypass tube became close to that at the run tube. Furthermore, experimental data showed that there was no significant variation in flow pattern and holdup between the run and main tubes. In order to calculate the holdup in the form of segregated flow, the drift flux model has been used here. |
Identificador | |
Idioma(s) |
英语 |
Fonte |
Chemical Engineering & Technology, 2008, 31(10): 1536-1540 |
Palavras-Chave | #Holdup #Tubes #Two-Phase Flow #T-Junction #Liquid #Pipes |