Failure of pyrolysis coils coated with anit-coking film in an ethylene cracking plant
Data(s) |
2014
|
---|---|
Resumo |
This paper presents a specific kind of failure in ethylene cracking coils coated with anticoking film. It investigates a case in which the coils made of 35Cr 45Ni high temperature alloy failed within two years of operation. The damage occurred due to heavy oxidation in localized regions of the coil resulting in the formation of blisters, which eventually failed by cracking. The mechanism involved was determined by studying the oxidized samples under a scanning electron microscope with an energy dispersive system and is attributed to the presence of rare earth metals in the anti-coking film and inherent casting defects in the base alloy. The cerium present in the anti-coking film diffused preferentially to a defect site in the parent alloy thereby resulting in its segregation which further led to embrittlement. (C) 2014 Elsevier Ltd. All rights reserved. |
Formato |
application/pdf |
Identificador |
http://eprints.iisc.ernet.in/49077/1/eng_fai_ana_39_181_2014.pdf Goswami, A and Kumar, S (2014) Failure of pyrolysis coils coated with anit-coking film in an ethylene cracking plant. In: ENGINEERING FAILURE ANALYSIS, 39 . pp. 181-187. |
Publicador |
PERGAMON-ELSEVIER SCIENCE LTD |
Relação |
http://dx.doi.org/10.1016/j.engfailanal.2014.01.019 http://eprints.iisc.ernet.in/49077/ |
Palavras-Chave | #Materials Engineering (formerly Metallurgy) |
Tipo |
Journal Article PeerReviewed |