Bubble size measurement and error analysis in a gas liquid ejector


Autoria(s): Suneetha, TB; Raghuram, PT
Data(s)

2012

Resumo

Bubble size in a gas liquid ejector has been measured using the image technique and analysed for estimation of Sauter mean diameter. The individual bubble diameter is estimated by considering the two dimensional contour of the ellipse, for the actual three dimensional ellipsoid in the system by equating the volume of the ellipsoid to that of the sphere. It is observed that the bubbles are of oblate and prolate shaped ellipsoid in this air water system. The bubble diameter is calculated based on this concept and the Sauter mean diameter is estimated. The error between these considerations is reported. The bubble size at different locations from the nozzle of the ejector is presented along with their percentage error which is around 18%.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/45790/1/Ind_Jol_Che_Tec_19-6_442_2012.pdf

Suneetha, TB and Raghuram, PT (2012) Bubble size measurement and error analysis in a gas liquid ejector. In: INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 19 (6). pp. 442-446.

Publicador

NATL INST SCIENCE COMMUNICATION-NISCAIR

Relação

http://nopr.niscair.res.in/handle/123456789/15142

http://eprints.iisc.ernet.in/45790/

Palavras-Chave #Chemical Engineering
Tipo

Journal Article

PeerReviewed