Evaluation of mechanical losses in a linear motor pressure wave generator
Contribuinte(s) |
Weisend, JG Barclay, J Breon, S Demko, J DiPirro, M Kittel, P Klebaner, A Marquardt, J Nellis, G Peterson, T Pfotenhauer, P Rowe, A VanSciver, S Yuan, S Zagarola, M Zeller, A |
---|---|
Data(s) |
2012
|
Resumo |
A moving magnet linear motor compressor or pressure wave generator (PWG) of 2 cc swept volume with dual opposed piston configuration has been developed to operate miniature pulse tube coolers. Prelimnary experiments yielded only a no-load cold end temperature of 180 K. Auxiliary tests and the interpretation of detailed modeling of a PWG suggest that much of the PV power has been lost in the form of blow-by at piston seals due to large and non-optimum clearance seal gap between piston and cylinder. The results of experimental parameters simulated using Sage provide the optimum seal gap value for maximizing the delivered PV power. |
Formato |
application/pdf application/pdf |
Identificador |
http://eprints.iisc.ernet.in/45410/7/AIP_proc_1434_1226_2012.pdf http://eprints.iisc.ernet.in/45410/6/AIP_proc_1434_1226_acc_ver_2012.pdf Jacob, S and Karunanithi, R and Kumar, Kranthi J and Damu, C and Achanur, M and Jagadish, G and Gour, AS (2012) Evaluation of mechanical losses in a linear motor pressure wave generator. In: Advances in Cryogenic Engineering: Transactions of the Cryogenic Engineering Conference - CEC, 13–17 June 2011, Spokane, Washington, USA, pp. 1226-1233. |
Publicador |
American Institute of Physics |
Relação |
http://dx.doi.org/10.1063/1.4707045 http://eprints.iisc.ernet.in/45410/ |
Palavras-Chave | #Centre for Cryogenic Technology |
Tipo |
Conference Proceedings PeerReviewed |