Bearing capacity of interfering multiple strip footings by using lower bound finite elements limit analysis


Autoria(s): Kumar, Jyant; Bhattacharya, Paramita
Data(s)

01/07/2010

Resumo

The ultimate bearing capacity of a number of multiple strip footings, identically spaced and equally loaded to failure at the same time,is computed by using the lower bound limit analysis in combination with finite elements. The efficiency factor due to the component of soil unit weight, is computed with respect to changes in the clear spacing (xi(gamma)) between the footings. It is noted that the failure load for a footing in the group becomes always greater than that of a single isolated footing. The values of xi(gamma) for the smooth footings are found to be always lower than the rough footings. The values ofxi(gamma) are found to increase continuously with a decrease in the spacing between footings. As compared to the available theoretical and experimental results reported in literature, the present analysis provides generally a little lower values of xi(gamma). (C) 2010 Elsevier Ltd. All rights reserved.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/31219/1/geotech.pdf

Kumar, Jyant and Bhattacharya, Paramita (2010) Bearing capacity of interfering multiple strip footings by using lower bound finite elements limit analysis. In: Computers and Geotechnics, 37 (5). pp. 731-736.

Publicador

Elsevier Science

Relação

http://dx.doi.org/10.1016/j.compgeo.2010.05.002

http://eprints.iisc.ernet.in/31219/

Palavras-Chave #Civil Engineering
Tipo

Journal Article

PeerReviewed