Simulation of Dust Loaded V-I Characteristics of a Commercial Thermal Power Plant Precipitator
Data(s) |
01/02/2010
|
---|---|
Resumo |
A new approach based on finite difference method, is proposed for the simulation of electrical conditions in a dc energized wire-duct electrostatic precipitator with and without dust loading. Simulated voltage-curren characteristics with and without dust loading were compared with the measured characteristics for analyzing the performance of a precipitator. The simple finite difference method gives sufficiently accurate results with reduced mesh size. The results for dust free simulation were validated with published experimental data. Further measurements were conducted at a thermal power plant in India and the results compares well with the measured ones. |
Formato |
application/pdf |
Identificador |
http://eprints.iisc.ernet.in/26243/1/getPDF.pdf Rajanikanth, BS and Jayan, MV (2010) Simulation of Dust Loaded V-I Characteristics of a Commercial Thermal Power Plant Precipitator. In: IEEE Transactions on Dielectrics and Electrical Insulation, 17 (1). pp. 39-44. |
Publicador |
IEEE. |
Relação |
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5412000&tag=1 http://eprints.iisc.ernet.in/26243/ |
Palavras-Chave | #Electrical Engineering |
Tipo |
Journal Article PeerReviewed |