Harmonic response of a shock mount employing dual-phase damping
Data(s) |
08/06/1975
|
---|---|
Resumo |
In this note, the application of dual-phase damping to a simple shock mount experiencing a harmonic input is described. The damping ratio is a function of the relative displacement between the foundation and the mounted mass. The purpose of employing such a damping is to reduce the absolute transmissibility over the whole frequency range. |
Formato |
application/pdf |
Identificador |
Venkatesan, C and Krishnan, R (1975) Harmonic response of a shock mount employing dual-phase damping. In: Journal of Sound and Vibration, 40 (3). 409 -413. |
Publicador |
Elsevier Science |
Relação |
http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6WM3-4X9P05X-9&_user=512776&_rdoc=1&_fmt=&_orig=search&_sort=d&_docanchor=&view=c&_acct=C000025298&_version=1&_urlVersion=0&_userid=512776&md5=492ed0f2d7461de81f43914b8c77e964 http://eprints.iisc.ernet.in/24100/ |
Palavras-Chave | #Computer Science & Automation (Formerly, School of Automation) |
Tipo |
Journal Article PeerReviewed |