Particle number emissions from a large fleet of diesel and CNG buses


Autoria(s): Jayaratne, Rohan; Morawska, Lidia; Ristovski, Zoran
Data(s)

23/08/2006

Resumo

Exhaust emissions were monitored in real-time at the kerb of a busy busway used by a mix of diesel and CNG-powered transport buses. Particle number concentration in the size range 3 nm to 3 µm was measured with a TSI condensation particle counter (CPC 3025). Particle mass (PM2.5) was measured with a TSI Dustrak 8520. The CO2 emissions were measured with a fast response CO2 analyser (Sable CA-10A). All emission concentrations were recorded in real time at 1 sec resolution, together with the precise passage times of buses. The instantaneous ratio of particle number (or mass) to CO2 concentration, denoted Z, was used as a measure of the particle number (or mass) emission factor of each passing bus.

Formato

application/pdf

Identificador

http://eprints.qut.edu.au/74612/

Relação

http://eprints.qut.edu.au/74612/3/74612.pdf

Jayaratne, Rohan, Morawska, Lidia, & Ristovski, Zoran (2006) Particle number emissions from a large fleet of diesel and CNG buses. In 10th ETH Conference on Combustion Generated Nanoparticles, 21-23 August 2006, ETH Zentrum, Zurich, Switzerland. (Unpublished)

Direitos

Copyright 2006 The Author(s)

Fonte

School of Chemistry, Physics & Mechanical Engineering; Institute of Health and Biomedical Innovation; Science & Engineering Faculty

Palavras-Chave #040101 Atmospheric Aerosols #050206 Environmental Monitoring #120506 Transport Planning #120599 Urban and Regional Planning not elsewhere classified #Diesel emissions #Nanoparticles #Natural Gas #Particle pollution #Urban pollution
Tipo

Conference Item